{"product_id":"uni-t-ut336a-refrigerant-leak-detector-wykrywacz-wyciekow-czynnika-chlodniczego-uni-t-ut336a","title":"Uni-T UT336A Refrigerant Leak Detector, Wykrywacz wycieków czynnika chłodniczego Uni-T UT336A","description":"\u003cp\u003e\u003c\/p\u003e\u003ch3\u003eUni-T UT336A Refrigerant Leak Detector\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe Uni-T UT336A is a compact refrigerant leak detector that uses a sensor based on the negative corona discharge phenomenon. The device offers high sensitivity up to 3 g\/year, warms up in just 3 seconds, and allows sensitivity to be adjusted across 6 levels, making it easier to adapt its operation to the location and working conditions. This model is ideal for servicing air conditioning systems, refrigeration systems, refrigerators, and automotive applications, and its audible and visual alarms help quickly locate the source of a leak.\u003c\/p\u003e\u003ch3\u003eAccurate performance and convenient operation\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe UT336A detects three main groups of halogenated refrigerants: CFCs, HCFCs, and HFCs, making it suitable for many common service tasks. The automatic reset function upon startup and the zeroing feature make it easy to begin measurements and improve detection accuracy in practice. Additional conveniences include a battery level indicator, mute mode, and automatic shut-off, which help conserve energy and extend the device’s operating time to up to 20 hours.\u003c\/p\u003e\u003ch3\u003eCompact design and ready for action\u003c\/h3\u003e\u003cbr\u003e\u003cp\u003eThe small housing and an additional auxiliary probe make it easier to work even in hard-to-reach places. It is a practical tool for daily leak diagnostics, designed for convenient use and a quick response to detected leaks. Compliance with CE and RoHS standards confirms that the device meets safety and quality requirements.\u003c\/p\u003e\u003cbr\u003e\u003ch3\u003eIncluded\u003c\/h3\u003e\u003cbr\u003e\u003cul class=\"list-disc pl-5\"\u003e\n\u003cli\u003eUni-T UT336A refrigerant leak detector\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eSafety instructions\u003c\/li\u003e\n\u003cli\u003e4 AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003eAuxiliary probe\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cdiv class=\"table-wrapper\"\u003e\n\u003cbr\u003e\u003cp\u003e \u003c\/p\u003e\n\u003cbr\u003e\u003ch3\u003e\u003c\/h3\u003e\n\u003cbr\u003e\u003ctable\u003e\n\u003cbr\u003e\u003ctbody\u003e\n\u003cbr\u003e\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eUni-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eUT336A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum sensitivity\u003c\/th\u003e\n\u003ctd\u003e3 g\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarm-up time\u003c\/th\u003e\n\u003ctd\u003e3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity adjustment\u003c\/th\u003e\n\u003ctd\u003e6 levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm\u003c\/th\u003e\n\u003ctd\u003eAudible and visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm levels\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported refrigerants\u003c\/th\u003e\n\u003ctd\u003eCFC, HCFC, HFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery status indicator\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eZeroing function\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbe lifespan\u003c\/th\u003e\n\u003ctd\u003eApprox. 50 h under normal operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating humidity\u003c\/th\u003e\n\u003ctd\u003ebelow 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e4 AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e190 × 65 × 43 mm (without probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNet weight\u003c\/th\u003e\n\u003ctd\u003e312 g (without batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003cbr\u003e\n\u003c\/tbody\u003e\n\u003cbr\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57628823683404,"sku":"UT336A","price":58.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2593\/1446\/files\/58066_3.jpg?v=1779709105","url":"https:\/\/beautychest.lt\/products\/uni-t-ut336a-refrigerant-leak-detector-wykrywacz-wyciekow-czynnika-chlodniczego-uni-t-ut336a","provider":"Beauty chest","version":"1.0","type":"link"}